APPLICATIONS > Power Generation 
   

Auxiliary power supply instrument transformers

Alternator instrument transformers | Auxiliary power supply instrument transformers | Generating sets instrument transformers | Wind and Solar energy instrument transformers | Busducts - GIS instrument transformers


1PB-MB-GB-RB-PB


Moulded case current transformers for the measurement of AC currents up to 150 A.


Notice M2AA

They are made of a non-flammable plastic material, and have heavy insulation. These current transformers are suitable for any application.

With their compact size and their high characteristics, they are particularly suitable for withdrawable switchboards.

MS


Moulded case current transformers for the measurement of AC currents from 50A to 1000A. measuring duties and is suitable for every simple application.


Notice M2DC

They are made of a non-flamable plastic material. This new range of current transformers has been designed for an easy installation : all transformers can be delivered with DIN rail clips. They are equipped as standard with a sealable terminal cover to comply with the most demanding safety requirements.

This range includes current transformers for measuring duties and is suitable for every simple application.

TA


Moulded case current transformers for the measurement of AC currents from 100A to 8000A.


Notice M2EA

They are made of a non-flamable plastic material and have heavy insulation. This comprehensive and compact range fits most busbars, from 30 to 160mm.

OREX


These ring type current transformers are available for indoor (ORX) or outdoor use (OREX). They have been designed to meet the requirements for measuring:
- line currents
- zero-sequence currents in the neutral of power transformers
- earth fault currents in power transformers.


Notice M2GM

The secondary terminals are accessible, either directly in the case of indoor equipment (ORX), or through a watertight terminal box in the case of outdoor application (OREX). Several types of terminal boxes are available depending on the required characteristics.

CRE


The change to newer, faster and more selective protective system makes it necessary to replace existing current transformers with different output, class, ratio, number of secondaries to suit the needs of the new protection.


Notice M2GS

The best solution is to use split-core current transformers on insulated cables or outside single phase metalclad units. This solution is very economical because:

- It is not necessary to dismantle and remake the cable sealing ends on the metalclad units.

- There is no need to recommission and test the main equipment.

- It reduces the risk of damage and the length of outages at reduced costs.

These current transformers are avalaible for indoor use (CR) or outdoor use (CRE).

TP


Voltage transformers and potential transformers for the measurement of AC voltages up to 2 000 V.
Main features include:
• Indoor
• Primary voltage up to 2000V
• Measurement and protection
• Protected construction, with unbreakable bushing insulators


Notice M2JA

T


Current transformers vacuum moulded in self extinguishing epoxy resin, for the measurement of AC currents up to 600A.


Notice M2NA

This range is also available with double-ratio up to 300-600A by primary change-over.

B2-B20-B32


Current transformers vacuum moulded in self extinguishing epoxy resin for the measurement of AC up to 800A.


Notice M2NB

This range is particularly suitable when primary connection using bars is required.

RC


Current transformers vacuum moulded in self extinguishing epoxy resin for the measurement of AC currents from 50 to 12 000A.


Notice M2OA

This range is particularly suitable for the measurement of high currents.

ISOBEL-ISO-C4-C8-C10


In addition to excellent mecanichal strength, these insulators have a high resistance to corrosive atmospheres and fire. They can be installed in any position.


Notice M2VN

ISOTRA-TIRE-TM-PA


Bushing insulators, with or without conductor for various applications in power generation or distribution.


Notice M2WN

RS ISOLSEC design and manufactureall types of bushing insulators or insulating parts in epoxy resin.

P80SB


Moulded case current transformer for the measurement of AC currents up to 150 A.


Wound-primary-transformer
Notice M2AB

This current transformer has been designed to meet the most demanding requirements, especially for protection relays.

Spacers can be inserted. Then rivets are replaced with screws.

1Psc-2Gsc-2Rsc-2Msc-P25-P40-P50-P60-P80


Moulded case current transformers for the measurement of AC currents up to 3000A, with inner diameters from 15 to 80 mm.


Notice M2CA

They are made of a non-flamable material and have heavy insulation. They are equipped as standard with EA type mounting brackets.

ORFE


These ring type current transformers are available for indoor (ORF) or outdoor use (ORFE). They have been designed to meet the requirements for metering and protection duties of:
- power transformers and auto-transformers
- HV or MV wall bushings
- GIS substation
- IPB
- Homopolar detection in neutral connections


Notice M2FP

The secondary terminals are accessible either directly in the case of indoor equipment (ORF) or through a watertight terminal box in the case of outdoor application (ORFE).

As per customer’s requirement, secondary windings can integrate time constant constraints.

TAxPEy


Outdoor current transformers for the measurement of AC currents up to 4000A.


Notice M2GN

They are moulded in selfextinguishing resin and have heavy insulation as standard. They are equipped with a weatherproof terminal box fitted with 2 cable glands.

This range complies with the European standards EN 50014 and 50019 «enhanced safety».

CRFE


The change to newer, faster and more selective protective system makes it necessary to replace existing current transformers with different output, class, ratio, number of secondaries to suit the needs of the new protection.


Notice M2GU

The best solution is to use split-core current transformers on insulated cables or outside single phase metalclad units. This solution is very economical because:

- It is not necessary to dismantle and remake the cable sealing ends on the metalclad units.

- There is no need to recommission and test the main equipment.

- It reduces the risk of damage and the length of outages at reduced costs.

These current transformers are avalaible for indoor use (CRF) or outdoor use (CRFE).

No fileVoltage limiter

English version coming soon!


Notice M2MA

RU


Single pole voltage transformer vacuum moulded in self extinguishing epoxy resin for the measurement of AC voltages between phase and earth up to 50 000/√3 V.


Notice M2RA

This range is also suitable for the power supply of auxiliaries up to 5 000VA.

RM


Double pole voltage transformer vacuum moulded in self extinguishing epoxy resin for the measure of AC voltages between phases up to 36 000 V, with rated outputs up to 100 VA cl0,2 or 150 VA cl0,5.


Notice M2SA

This range is also suitable for the power supply of auxiliaries up to 2 500VA clA.

UT-CT


Single or double pole voltage transformer vacuum moulded in self extinguishing epoxy resin for the measure of AC voltages between phases or between phase and earth up to 36 000 V.


Notice M2TA

These compact size transformers are equiped with one or two a 6.3 A rating fuse.

This range is also suitable for the power supply of auxiliaries up to 2 500VA clA.

MA-MT


Voltage transformers vacuum moulded in self extinguishing epoxy resin.


Notice M2UA

This compact range is suitable for the power supply of auxiliaries in generators.

© RS ISOLSEC - Instrument transformers