APPLICATIONS > Distribution of Electrical Energy 
   

Differential instrument transformers

Distribution substation - Generation substation instrument transformers | MV Switchgear instrument transformers | MV & MV/LV Power Transformer instrument transformers | Auxiliary power supply instrument transformers | Differential instrument transformers | Network Management instrument transformers | Reactive power compensation instrument transformers | Tariff Metering instrument transformers


OREX


These ring type current transformers are available for indoor (ORX) or outdoor use (OREX). They have been designed to meet the requirements for measuring:
- line currents
- zero-sequence currents in the neutral of power transformers
- earth fault currents in power transformers.


Notice M2GM

The secondary terminals are accessible, either directly in the case of indoor equipment (ORX), or through a watertight terminal box in the case of outdoor application (OREX). Several types of terminal boxes are available depending on the required characteristics.

TA11PE80-1


Ces transformateurs de mesure sont en résine époxy moulée autoextinguible et possèdent de série un isolement renforcé.


Notice M2GP

Ils sont équipés d’un capot étanche muni de 2 presse étoupes. Cette gamme est conforme aux exigences des normes EN 50014 et EN 50019 “sécurité augmentée”.

English version coming soon!

CRFE


The change to newer, faster and more selective protective system makes it necessary to replace existing current transformers with different output, class, ratio, number of secondaries to suit the needs of the new protection.


Notice M2GU

The best solution is to use split-core current transformers on insulated cables or outside single phase metalclad units. This solution is very economical because:

- It is not necessary to dismantle and remake the cable sealing ends on the metalclad units.

- There is no need to recommission and test the main equipment.

- It reduces the risk of damage and the length of outages at reduced costs.

These current transformers are avalaible for indoor use (CRF) or outdoor use (CRFE).

TAxPEy


Outdoor current transformers for the measurement of AC currents up to 4000A.


Notice M2GN

They are moulded in selfextinguishing resin and have heavy insulation as standard. They are equipped with a weatherproof terminal box fitted with 2 cable glands.

This range complies with the European standards EN 50014 and 50019 «enhanced safety».

CRE


The change to newer, faster and more selective protective system makes it necessary to replace existing current transformers with different output, class, ratio, number of secondaries to suit the needs of the new protection.


Notice M2GS

The best solution is to use split-core current transformers on insulated cables or outside single phase metalclad units. This solution is very economical because:

- It is not necessary to dismantle and remake the cable sealing ends on the metalclad units.

- There is no need to recommission and test the main equipment.

- It reduces the risk of damage and the length of outages at reduced costs.

These current transformers are avalaible for indoor use (CR) or outdoor use (CRE).

DIVI


This range of voltage dividers is for cheking the presence of voltage on the busbar. The neon lamp is not supplied with the voltage divider.


Notice M2WA