Process Control and Electric Motor instrument transformers | Electrical engine control command instrument transformers | Relay supply instrument transformers | Electrical Network Management instrument transformers | Reactive Energy Compensation instrument transformers | Industrial metering instrument transformers | Wall bushings - Insulators


TR33 - TR66


This CT range is in cast resin, with excellent withstand to severe environment in terms of temperature, vibrations, salt, moisture and contaminants.


Notice M2EE

Secondary terminal connections are flying leads, to avoid any potential risk of loosening connections, or vibration resonance that may break terminals. TR33xy and TR66xy are designed to adapt to various busbar sizes, and accommodate large cores and windings to match demanding requirements in protection and accuracy classes. Fixing is performed tightening 2 horse shoe-shape clips on amagnetic support plate, enabling very strong hold on busbar.

P80SB


Moulded case current transformer for the measurement of AC currents up to 150 A.


Wound-primary-transformer
Notice M2AB

This current transformer has been designed to meet the most demanding requirements, especially for protection relays.

Spacers can be inserted. Then rivets are replaced with screws.

TA


Moulded case current transformers for the measurement of AC currents from 100A to 8000A.


Notice M2EA

They are made of a non-flamable plastic material and have heavy insulation. This comprehensive and compact range fits most busbars, from 30 to 160mm.

TR


Current transformers moulded in self-extinguishing resin for the measurement of AC currents from 150 to 15 000A.


Notice M2EB

This range has high performance characteristics, and demonstrates an excellent resistance to shocks, vibrations, salt and moisture.

It is approved by the french Navy.

B "CEPOY"


Current transformers moulded in self extinguishing resin for the measurement of AC currents from 50 to 60 000A.


Notice M2FN

With inner diameters between 106 and 500 mm, these transformers are often used on bushings of power transformers or on generator bushing insulators. 

2 versions, indoor or outdoor, are available. The outdoor version is equipped with a weatherproof terminal box fitted with 2 cable glands.

CRE


The change to newer, faster and more selective protective system makes it necessary to replace existing current transformers with different output, class, ratio, number of secondaries to suit the needs of the new protection.


Notice M2GS

The best solution is to use split-core current transformers on insulated cables or outside single phase metalclad units. This solution is very economical because:

- It is not necessary to dismantle and remake the cable sealing ends on the metalclad units.

- There is no need to recommission and test the main equipment.

- It reduces the risk of damage and the length of outages at reduced costs.

These current transformers are avalaible for indoor use (CR) or outdoor use (CRE).

B2-B20-B32


Current transformers vacuum moulded in self extinguishing epoxy resin for the measurement of AC up to 800A.


Notice M2NB

This range is particularly suitable when primary connection using bars is required.

TA301-7 - P80-17


Current transformers for the measurement of AC currents from 40 to 8 000A.


Notice M2OB

This low cost range couples a low voltage current transformer and an insulating epoxy tube.

J36B


Current transformers vacuum moulded in self extinguishing epoxy resin for the measure of AC currents from 0 up to 2500A - 36kV.


Notice M2PC

This comprehensive and compact range of current transformers has been designed to meet the requirements of MV switchgear manufacturers. It allows double ratios up to 600-1200 A, and offers up to 4 independent cores.

RM


Double pole voltage transformer vacuum moulded in self extinguishing epoxy resin for the measure of AC voltages between phases up to 36 000 V, with rated outputs up to 100 VA cl0,2 or 150 VA cl0,5.


Notice M2SA

This range is also suitable for the power supply of auxiliaries up to 2 500VA clA.

1Psc-2Gsc-2Rsc-2Msc-P25-P40-P50-P60-P80


Moulded case current transformers for the measurement of AC currents up to 3000A, with inner diameters from 15 to 80 mm.


Notice M2CA

They are made of a non-flamable material and have heavy insulation. They are equipped as standard with EA type mounting brackets.

JF


Current transformers moulded in self extinguishing resin for the measure of AC currents from 50 up to 5000A.


Notice M2CC

Two versions, indoor or outdoor, are available. The outdoor version is equipped with a weatherproof terminal box fitted with 2 cable glands.

JFD


Current transformers moulded in self extinguishing resin for the measure of AC currents from 50 up to 5000A.


Notice M2FM

With inner diameters from 200 to 400 mm, these transformers are often used on power transformers bushings or on generator bus bars. Two versions, indoor or outdoor, are available. The outdoor version is equipped with a weatherproof terminal box fitted with two cable glands.

OREX


These ring type current transformers are available for indoor (ORX) or outdoor use (OREX). They have been designed to meet the requirements for measuring:
- line currents
- zero-sequence currents in the neutral of power transformers
- earth fault currents in power transformers.


Notice M2GM

The secondary terminals are accessible, either directly in the case of indoor equipment (ORX), or through a watertight terminal box in the case of outdoor application (OREX). Several types of terminal boxes are available depending on the required characteristics.

CRFE


The change to newer, faster and more selective protective system makes it necessary to replace existing current transformers with different output, class, ratio, number of secondaries to suit the needs of the new protection.


Notice M2GU

The best solution is to use split-core current transformers on insulated cables or outside single phase metalclad units. This solution is very economical because:

- It is not necessary to dismantle and remake the cable sealing ends on the metalclad units.

- There is no need to recommission and test the main equipment.

- It reduces the risk of damage and the length of outages at reduced costs.

These current transformers are avalaible for indoor use (CRF) or outdoor use (CRFE).

RC


Current transformers vacuum moulded in self extinguishing epoxy resin for the measurement of AC currents from 50 to 12 000A.


Notice M2OA

This range is particularly suitable for the measurement of high currents.

CB


Current transformers vacuum moulded in self extinguising epoxy resin for the measurement of AC currents up to 3000A.


Notice M2PA

This comprehensive and compact range of current transformers has been designed to meet the requirements of MV switchgear manufacturers. It offers a very low level of partial discharges. It allows double-ratio up to 600-1200A by primary coupling, as well as up to 5 independant secondary windings.

J24B


Current transformers vacuum moulded in self extinguishing epoxy resin for the measure of AC currents from 0 up to 2500A - 24kV.


Notice M2PB

This comprehensive and compact range of current transformers has been designed to meet the requirements of MV switchgear manufacturers. It allows double ratios up to 600-1200A, and offers up to 4 independent cores.

DIVI


This range of voltage dividers is for cheking the presence of voltage on the busbar. The neon lamp is not supplied with the voltage divider.


Notice M2WA