APPLICATIONS > Distribution of Electrical Energy 
   

Network Management instrument transformers

Distribution substation - Generation substation instrument transformers | MV Switchgear instrument transformers | MV & MV/LV Power Transformer instrument transformers | Auxiliary power supply instrument transformers | Differential instrument transformers | Network Management instrument transformers | Reactive power compensation instrument transformers | Tariff Metering instrument transformers


1PB-MB-GB-RB-PB


Moulded case current transformers for the measurement of AC currents up to 150 A.


Notice M2AA

They are made of a non-flammable plastic material, and have heavy insulation. These current transformers are suitable for any application.

With their compact size and their high characteristics, they are particularly suitable for withdrawable switchboards.

JM


Current transformers moulded in self extinguishing casings for the measure of AC currents from 1 up to 600A.


Notice M2AC

Features heavy duty insulation.

This compact range fits most switchboards used for measure.

P80S25-P80S40-P80S50-P80S60


Moulded case current transformers for the measurement of AC currents up to 3000A, with inner diameters from 25mm up to 60mm.


Notice M2CB

They are made of a non-flamable plastic material and have heavy insulation. They are equipped as standard with EA mounting brackets.

This range has been designed to meet the demanding requirements of protection relays.

TA


Moulded case current transformers for the measurement of AC currents from 100A to 8000A.


Notice M2EA

They are made of a non-flamable plastic material and have heavy insulation. This comprehensive and compact range fits most busbars, from 30 to 160mm.

JX


Current transformers moulded in self extinguishing casings for the measure of AC currents from 50 up to 2000A.


Notice M2ED

Features heavy duty insulation. This compact range fits 20 mm busbars.

OREX


These ring type current transformers are available for indoor (ORX) or outdoor use (OREX). They have been designed to meet the requirements for measuring:
- line currents
- zero-sequence currents in the neutral of power transformers
- earth fault currents in power transformers.


Notice M2GM

The secondary terminals are accessible, either directly in the case of indoor equipment (ORX), or through a watertight terminal box in the case of outdoor application (OREX). Several types of terminal boxes are available depending on the required characteristics.

CRFE


The change to newer, faster and more selective protective system makes it necessary to replace existing current transformers with different output, class, ratio, number of secondaries to suit the needs of the new protection.


Notice M2GU

The best solution is to use split-core current transformers on insulated cables or outside single phase metalclad units. This solution is very economical because:

- It is not necessary to dismantle and remake the cable sealing ends on the metalclad units.

- There is no need to recommission and test the main equipment.

- It reduces the risk of damage and the length of outages at reduced costs.

These current transformers are avalaible for indoor use (CRF) or outdoor use (CRFE).

TP


Voltage transformers and potential transformers for the measurement of AC voltages up to 2 000 V.
Main features include:
• Indoor
• Primary voltage up to 2000V
• Measurement and protection
• Protected construction, with unbreakable bushing insulators


Notice M2JA

OTC-OT


Three phase voltage transformers and potential transformers for the measurement of AC voltages up to 2 000V.
Main features include:
• Indoor
• Primary voltage up to 2000V
• Unprotected construction


Notice M2JN

B2-B20-B32


Current transformers vacuum moulded in self extinguishing epoxy resin for the measurement of AC up to 800A.


Notice M2NB

This range is particularly suitable when primary connection using bars is required.

RT


Double pole voltage transformer vacuum moulded in self extinguishing epoxy resin for the measure of AC voltages between phases up to 36 000 V, with rated outputs up to 200 VA cl0,2 or 300 VA cl0,5.


Notice M2SB

This range is also suitable for the power supply of auxiliaries up to 5 000VA clA.

UT-CT


Single or double pole voltage transformer vacuum moulded in self extinguishing epoxy resin for the measure of AC voltages between phases or between phase and earth up to 36 000 V.


Notice M2TA

These compact size transformers are equiped with one or two a 6.3 A rating fuse.

This range is also suitable for the power supply of auxiliaries up to 2 500VA clA.

RU12E-RM20E-RM25E-RM30E


Single or double pole outdoor voltage transformer vacuum moulded in self extinguishing epoxy resin for the measure of AC voltages between phases or between phase and earth up to 36 000 V.


Notice M2TB

Available with rated outputs up to 50 VA cl0,5 or 100 VA cl1. They are equipped with a weatherproof terminal box fitted with 2 cable glands.

This range is also suitable for the power supply of auxiliaries up to 2 500 VA clA.

DIVI


This range of voltage dividers is for cheking the presence of voltage on the busbar. The neon lamp is not supplied with the voltage divider.


Notice M2WA

P80SB


Moulded case current transformer for the measurement of AC currents up to 150 A.


Wound-primary-transformer
Notice M2AB

This current transformer has been designed to meet the most demanding requirements, especially for protection relays.

Spacers can be inserted. Then rivets are replaced with screws.

1P-2P-2M-2G-2R-3P


Moulded case current transformers for the measurement of AC currents from 40 to 600 A.


Notice M2BA

They are made of a non-flamable plastic material, and have heavy insulation. They are equipped with a central bush for mounting between 2 bars or 1 bar and 1 cable lug. These current transformers are suitable for all applications. With their compact size, they are particularly suitable for withdrawable switchboards.

MS


Moulded case current transformers for the measurement of AC currents from 50A to 1000A. measuring duties and is suitable for every simple application.


Notice M2DC

They are made of a non-flamable plastic material. This new range of current transformers has been designed for an easy installation : all transformers can be delivered with DIN rail clips. They are equipped as standard with a sealable terminal cover to comply with the most demanding safety requirements.

This range includes current transformers for measuring duties and is suitable for every simple application.

JR


Current transformers moulded in self extinguishing casings for the measure of AC currents from 400 up to 4000A.


Notice M2EC

Features heavy duty insulation. This compact range fits busbars from 30 to 100 mm.

B "CEPOY"


Current transformers moulded in self extinguishing resin for the measurement of AC currents from 50 to 60 000A.


Notice M2FN

With inner diameters between 106 and 500 mm, these transformers are often used on bushings of power transformers or on generator bushing insulators. 

2 versions, indoor or outdoor, are available. The outdoor version is equipped with a weatherproof terminal box fitted with 2 cable glands.

CRE


The change to newer, faster and more selective protective system makes it necessary to replace existing current transformers with different output, class, ratio, number of secondaries to suit the needs of the new protection.


Notice M2GS

The best solution is to use split-core current transformers on insulated cables or outside single phase metalclad units. This solution is very economical because:

- It is not necessary to dismantle and remake the cable sealing ends on the metalclad units.

- There is no need to recommission and test the main equipment.

- It reduces the risk of damage and the length of outages at reduced costs.

These current transformers are avalaible for indoor use (CR) or outdoor use (CRE).

PBT-P80ST


Current transformers for the summation of 2 to 12 different currents of the same phase, supplied by the secondaries of 2 to 12 transformers with identical or different ratios.


Notice M2HA

There are 2 models, PBT or P80ST, selected according to requirements. They are delivered with EA mounting brackets.

No fileVoltage limiter

English version coming soon!


Notice M2MA

RC


Current transformers vacuum moulded in self extinguishing epoxy resin for the measurement of AC currents from 50 to 12 000A.


Notice M2OA

This range is particularly suitable for the measurement of high currents.

HT


Current transformers vacuum moulded in self extinguishing epoxy resin for the measurement of AC currents from 100 to 30 000A.


Notice M2OC

This range of transformers is suitable for power generation. They have been designed to be installed in bus ducts between generator and transformer. They enable very high performance to be achieved.

RU


Single pole voltage transformer vacuum moulded in self extinguishing epoxy resin for the measurement of AC voltages between phase and earth up to 50 000/√3 V.


Notice M2RA

This range is also suitable for the power supply of auxiliaries up to 5 000VA.

RM


Double pole voltage transformer vacuum moulded in self extinguishing epoxy resin for the measure of AC voltages between phases up to 36 000 V, with rated outputs up to 100 VA cl0,2 or 150 VA cl0,5.


Notice M2SA

This range is also suitable for the power supply of auxiliaries up to 2 500VA clA.

CB


Current transformers vacuum moulded in self extinguising epoxy resin for the measurement of AC currents up to 3000A.


Notice M2PA

This comprehensive and compact range of current transformers has been designed to meet the requirements of MV switchgear manufacturers. It offers a very low level of partial discharges. It allows double-ratio up to 600-1200A by primary coupling, as well as up to 5 independant secondary windings.

CME


Single or three phase assembly made of respectively 1 voltage transformer and 1 current transformer, or 3 voltage transformers and 3 current transformers, for outdoor use.


Notice M2XA

For measuring AC voltages between phases or phase to earth, and for AC currents from 0 to 2500 A, up to 36 000/√3 V. Delivered mounted on a metallic base, they are equipped with a secondary wiring for direct connexion to the switchboard terminal.